2-3/4"W x 4-1/2"H x 1-1/4"D (69.8mm x 114.3mm x 31.7mm)
Memory
120 users. Non-volatile EEPROM memory means your codes and instructions will be there whether you remove power for five minutes or five years. This is standard on all models.
Main Relay
9212i series features a SPDT relay (9212i rated at 5A @ 24VDC and 9212iLW rated at 2A) tough enough to handle virtually any low-voltage equipment or electronic locking device.
Remote Triggering Input
Each keypad provides a normally open input loop for remote triggering. Simple programming allows for a momentary closure upon this loop to trigger any combination of outputs. This feature is especially useful when controlling an electric locking device.
Programming
All programming is accomplished entirely from the front of the keypad. LED and/or sounder guidance makes programming a snap and changing codes a matter of seconds for an authorized user.
Auxiliary Outputs
Each output to be individually timed from 1 to 90 seconds or act as a toggle switch. Outputs may be triggered individually or in combination by any user code. Outputs have 50mA negative voltage outputs.
Number of Users
Up to 120
Voltage Input
12 or 24 VAC/VDC
Warranty
Two Year Limited Warranty
Weight
1.0000
Rutherford Controls RCI 9212i Interior Use Stand-Alone Keypad