12” x 16” x 4” deep NEMA enclosure will accommodate one or two relay modules with the built-in power supply. Additional modules may require larger enclosures.
Dimensions (PC Board)
Module - 5” x 3” overal controls two doors
Power Requirements
AC Input - Fused 110 VAC
DC Output - 4 amp field selectable 12 or 24 VDC
Output Voltage
Field selectable 12 or 24 VDC
Inputs
Two Dry Contact Inputs for Door Status (Contact closed when is door secure)
Two Dry Contact Inputs for Request to Access (Contact normally open)
Two Dry Contact Inputs for Remote Override
Outputs
Two Relay Outputs - SPDT powered outputs for direct connection to locks. 3 Amps Max.
Two Relay Outputs – SPDT dry contact rated for 3 Amps@ 28 VDC mirror lock status for traffic lights or signalling a remote console.
Warranty
1 Year Warranty
Weight
20.0000
43211-U — Dortronics Power Supply 4300 Series 2 Door Mantrap Interlocks, 2 Doors - 1 Room, All Doors Normally Unlocked